当前位置:首页-新闻中心新闻中心

使用螺旋风管比传统矩形风管的优势有哪些?

发布人:http://www.sftfgd.com   发布时间:2021-09-09 13:53:22

1.相同的环境与条件下,可由低速排风调整高速排风,系统设计可减少风管总量,不仅经济,而且节约空间

1. Under the same environment and conditions, it can be adjusted from low-speed exhaust to high-speed exhaust. The system design can reduce the total amount of air duct, which is not only economical, but also saves space

2.同等条件下满状辅材(吊键等)结果简单,数量少,安装辅材造价降低20%到35%

2. Under the same conditions, the results of full auxiliary materials (hanging keys, etc.) are simple, the quantity is small, and the cost of installing auxiliary materials is reduced by 20% to 35%

3.施工时吊装效率比矩形风管提高一倍

3. During construction, the hoisting efficiency is twice as high as that of rectangular air duct

4.相比传统矩形风管,螺旋风管的主材造价降低15%左右,同等管径,板厚降低13-17%。主材造价降低.

4. Compared with the traditional rectangular air duct, the main material cost of spiral air duct is reduced by about 15%, and the plate thickness is reduced by 13-17% with the same pipe diameter. The cost of main materials is reduced

螺旋风管比传统矩形风管更具备优越性

Spiral duct has more advantages than traditional rectangular duct

1.)圆形风管比矩形风管结构更加合理,在降低降低颤震噪音方面要优于传统矩形风管

  1. ) the structure of circular air duct is more reasonable than that of rectangular air duct, and it is better than traditional rectangular air duct in reducing vibration noise

  2. QQ截图20170428145524.png

2.)连接部件少,在系统通风质量与密封性能方面螺旋风管比矩形风管要好

2.) there are few connecting parts, and the spiral air duct is better than the rectangular air duct in terms of system ventilation quality and sealing performance

3.)螺旋风管外型比矩形风管更美观

3.) spiral air duct is more beautiful than rectangular air duct

镀锌螺旋风管

Galvanized spiral air duct

风管采用镀锌钢板,其厚度应符合GB50243-2002下表选用以下规定。形风管的弯管,可采用内弧型或内斜线矩形弯管。当边长A大于或等于500mm时,应设置弯管导流片。矩形风管的三通或四通,可采用分叉式或分隔式。风管与法兰连接,翻边应平整,宽度应一致且不小于6mm,并不得有开裂及孔洞,对角及翻边缝应涂上密封胶。法兰用料规格见下表: 风管法兰制作应先做好模具。模具做好后检查模具的几何尺寸,对角线是否符合设计及规范要求,检查无误后进行下料、校直、钻铆钉孔(孔距不大于150mm)、组装、焊接、钻孔。另外对边长大于800的风管应加固措施。风管及法兰尺寸的允许偏差和检验方法见下表:

The air duct shall be made of galvanized steel plate, and its thickness shall comply with the following provisions in the following table of GB50243-2002. For the elbow of V-shaped air duct, the inner arc or inner oblique rectangular elbow can be adopted. When the side length a is greater than or equal to 500mm, elbow deflector shall be set. The tee or cross of rectangular air duct can be bifurcated or separated. When the air duct is connected with the flange, the flanging shall be flat, the width shall be consistent and not less than 6mm, and there shall be no cracks and holes. The diagonal and flanging joints shall be coated with sealant. See the following table for the specifications of flange materials: the mold shall be made first for the fabrication of air duct flange. After the mold is completed, check whether the geometric dimension and diagonal line of the mold meet the design and specification requirements. After the inspection is correct, blanking, straightening, drilling rivet holes (hole spacing not greater than 150mm), assembly, welding and drilling shall be carried out. In addition, reinforcement measures shall be taken for air ducts with side length greater than 800. The allowable deviation and inspection method of air duct and flange size are shown in the table below:

风管安装过程中,进行风管分段检漏测试。风管制作安装后,要检验合格才交付下步保温工序。风管吊杆的末端要满足调节风管标高的要求,吊杆制作好后,根据风管的布置位置进行安装,水平风管的间距不大于3m,垂直风管不大于4m。风管支吊架、防火阀、电动风阀等部件安装处须单独设支吊架处,一般风管每隔3米左右设支吊架一个,支吊架的作法可参照采暖通风**标准图集。风管支、吊架不得设置在风口、阀门、检查门及自控机构处。吊杆不得直接固.

During the installation of air duct, conduct sectional leak detection test of air duct. After the air duct is manufactured and installed, it shall be delivered to the next insulation process only after passing the inspection. The end of the air duct suspender shall meet the requirements for adjusting the elevation of the air duct. After the suspender is fabricated, it shall be installed according to the layout position of the air duct. The spacing between horizontal air ducts shall not be greater than 3m and vertical air ducts shall not be greater than 4m. Air duct supports and hangers, fire dampers, electric air valves and other components shall be installed separately. Generally, air ducts shall be provided with one support and hanger every 3M. The method of support and hanger can refer to the standard atlas of heating and ventilation * *. Air duct supports and hangers shall not be set at air outlets, valves, inspection doors and automatic control mechanisms. The suspender shall not be fixed directly

以上的信息就是济南通风管道给小编提供的知识分享,更多的精彩内容请点击我们的网站:http://www.sftfgd.com我们后续会有更多的内容等您查看

The above information is the knowledge sharing provided by Jinan ventilation pipeline to Xiaobian. For more wonderful contents, please click our website: http://www.sftfgd.com We will have more content for you to check later


上一篇:日常常见的山东通风管道有哪些材质?
下一篇:除尘管道布置可按照哪些方法操作?

网站首页 关于我们 产品展示 新闻中心 工程案例 在线留言 联系我们